Euler Buckling Calculator
Calculate the ideal Euler critical axial load of a slender column from modulus, second moment, length and end factor.
Formula
Pcr = π² E I/(K L)²; E in GPa is multiplied by 1,000.
Euler critical load ≈ pi^2×(200)×1000×(1,000)÷((1)×(1,000))^2
How to use
- Enter Young's modulus and the least second moment of area.
- Enter column length and effective-length factor K.
- Read the ideal elastic buckling load.
Examples
- E = 200 GPa, I = 1,000 mm⁴, L = 1,000 mm and K = 1 give 1,973.921 N.
Frequently asked questions
Which second moment is required?
Use the least second moment about the possible buckling axes.
What is K?
The effective-length factor for the actual end restraints; supply the appropriate value.
Is this an allowable design load?
No. Euler assumes a slender, straight, elastic column under concentric compression, without safety factors.
Sources
Updated: