KiloAtlas
EN
EnglishBahasa IndonesiaTiếng Việt

Euler Buckling Calculator

Calculate the ideal Euler critical axial load of a slender column from modulus, second moment, length and end factor.

Euler critical load

1,973.921N

Formula

Pcr = π² E I/(K L)²; E in GPa is multiplied by 1,000.

Euler critical load ≈ pi^2×(200)×1000×(1,000)÷((1)×(1,000))^2

How to use

  1. Enter Young's modulus and the least second moment of area.
  2. Enter column length and effective-length factor K.
  3. Read the ideal elastic buckling load.

Examples

  • E = 200 GPa, I = 1,000 mm⁴, L = 1,000 mm and K = 1 give 1,973.921 N.

Frequently asked questions

Which second moment is required?

Use the least second moment about the possible buckling axes.

What is K?

The effective-length factor for the actual end restraints; supply the appropriate value.

Is this an allowable design load?

No. Euler assumes a slender, straight, elastic column under concentric compression, without safety factors.

Sources

Updated:

Related tools

Search conversion tools