Estimate steady heat flow through one building element using its effective U-value, area and indoor–outdoor temperature difference.

Outward heat flow Q̇

200W

Formula

Q̇ = UA(Tᵢ−Tₒ)

Outward heat flow Q̇ ≈ (0.5)×(20)×((20)-(0))

How to use

  1. Enter the element's effective U-value and area.
  2. Enter indoor and outdoor temperatures.
  3. Read heat flow, positive for outward heat loss.

Examples

  • U=0.5 W/(m²·K), area 20 m² and a 20 K difference give 200 W of heat loss.

Frequently asked questions

What does U include?

Use the overall transmittance for the complete element and its surface resistances.

Does this estimate the whole heating load?

No. It covers one element; ventilation, infiltration, thermal bridges and transient effects are excluded.

Why is heat flow negative?

Outdoors is warmer than indoors, so this element gains heat under the model.