Ideal Transformer Calculator
Calculate secondary voltage and current from turn counts and primary values.
Formula
Vs = Vp Ns/Np; Is = Ip Np/Ns.
Secondary voltage ≈ (120)×(50)÷(100) · Secondary current ≈ (2)×(100)÷(50)
How to use
- Enter primary and secondary turns.
- Enter primary RMS voltage and current.
- Read secondary RMS values.
Examples
- 100:50 turns, 120 V and 2 A give 60 V and 4 A.
Frequently asked questions
Are losses included?
No; magnetic coupling and efficiency are ideal.
Does it work with DC?
Use steady sinusoidal AC values.
Why does current decrease?
An increased voltage preserves power by reducing current.