Kinematic Viscosity of Air Calculator
Estimate dry-air density and viscosity using absolute pressure, absolute temperature and Sutherland's relation.
Formula
ρ=1000P/(287.05T); μ=1.458T^1.5/(T+110.4) μPa·s; ν=μ/ρ mm²/s.
Density ρ ≈ (101.3)×1000÷(287.05×(300)) · Dynamic viscosity μ ≈ 1.458×(300)^1.5÷((300)+110.4) · Kinematic viscosity ν ≈ (18.46001519)÷(1.176333972)
How to use
- Enter temperature in kelvins.
- Enter absolute pressure in kPa.
- Read density and both viscosities.
Examples
- At 400 K and 114.82 kPa, density is 1 kg/m³.
Frequently asked questions
May I enter gauge pressure?
No. Convert it to absolute pressure first.
Is humidity included?
No. This model treats dry air as an ideal gas.
Is this a precise material table?
No. The Sutherland equation is an empirical approximation.
Sources
Updated: