Process Capability Index Calculator
Calculate Cp, Cpu, Cpl and Cpk from specification limits, the process mean and a positive standard deviation.
Formula
Cp=(USL−LSL)/(6σ); Cpu=(USL−μ)/(3σ); Cpl=(μ−LSL)/(3σ); Cpk=min(Cpu,Cpl).
Cp ≈ sqrt((12)-(0))^2÷(6×(2)) · Cpu ≈ ((12)-(6))÷(3×(2)) · Cpl ≈ ((6)-(0))÷(3×(2)) · Cpk ≈ min((1),(1))
How to use
- Enter LSL and USL with USL greater than LSL.
- Enter the mean and positive within-process standard deviation.
- Read the capability indices for a stable process.
Examples
- LSL=0, USL=12, μ=6 and σ=2 give Cp=Cpk=1.
Frequently asked questions
Are control limits the same?
No; enter specification limits set for the product or process.
Can Cpk be negative?
Yes, if the mean lies outside a specification limit.
What assumptions apply?
Capability interpretation assumes a stable process and approximately normal measurements; thresholds depend on requirements.
Sources
Updated: