Solenoid Magnetic Field Calculator
Estimate magnetic flux density inside a long solenoid from current, turns, length and permeability.
Formula
B = μNI/l; μ in µH/m gives B = μNI/(1000l) mT.
Flux density B ≈ (1.257)×(100)×(1)÷(1000×(0.1))
How to use
- Enter turns, current magnitude and winding length.
- Enter effective core permeability in µH/m.
- Read the internal flux density in mT.
Examples
- 100 turns, 1 A, 0.1 m and μ = 1.2 µH/m give 1.2 mT.
Frequently asked questions
Where is the field calculated?
Inside a long solenoid, away from its ends.
Does this give field direction?
No. Use the right-hand rule for the winding current.
Does it include core saturation?
No. Permeability must suit the linear operating range.
Sources
Updated: