Water Heating Calculator
Estimate sensible heat and heating time or required power from mass, heat capacity, temperature rise and efficiency.
Formula
Q = mcΔT; t = Q/(Pη); P = Q/(tη); η = efficiency/100.
Sensible heat ≈ (1)×(4,184)×(60) · Heating time ≈ 100×(251,040)÷((2,000)×(90)) · Heating power ≈ (2,000)
How to use
- Choose known power in W or known time in seconds.
- Enter mass, heat capacity, temperature rise and efficiency.
- Read heat and the required time or power.
Examples
- 1 kg, c=4,000 J/(kg·K), rise 20 K and 1,000 W at 100% take 80 s.
Frequently asked questions
Can water boil in this model?
No; this model excludes phase changes and latent heat.
Can I change heat capacity?
Yes; enter a suitable mean value for your material and temperature range.
How are heat losses handled?
Use an estimated overall efficiency; the vessel heat capacity is not modeled separately.
Sources
Updated: