Wind Turbine Power Calculator

Estimate rotor power from air density, swept area, steady wind speed and a supplied power coefficient.

Rotor power

2.4kW

Formula

P (kW) = 0.5ρAv³Cp / 1000; 0 ≤ Cp ≤ 16/27.

Rotor power ≈ 0.5×(1.2)×(10)×(10)^3×(0.4)÷1000

How to use

  1. Enter air density and rotor swept area.
  2. Enter steady wind speed and power coefficient Cp.
  3. Read estimated rotor power in kilowatts.

Examples

  • ρ=1.2 kg/m³, A=10 m², v=10 m/s and Cp=0.4 give 2.4 kW.

Frequently asked questions

What is the swept area?

For a circular rotor it is π times radius squared; enter the area perpendicular to wind.

Why limit Cp to 16/27?

The Betz limit bounds energy extraction by an ideal unshrouded rotor; practical coefficients are lower.

Is this annual electricity generation?

No. It assumes steady wind and excludes generator losses, cut-in, cut-out and rated-power limits.