KiloAtlas
EN
EnglishBahasa IndonesiaTiếng Việt

Y Plus Calculator

Calculate dimensionless wall distance y+ and friction velocity from wall shear stress, fluid density, viscosity and wall distance.

Friction velocity

2m/s
Dimensionless wall distance y+
1 1

Formula

uτ=√(τw/ρ); y+=yρuτ/μ, with y in meters.

Friction velocity ≈ sqrt((4)÷(1)) · Dimensionless wall distance y+ ≈ (0.5)÷1000×(1)×(2)÷(0.001)

How to use

  1. Enter fluid density and wall shear stress magnitude.
  2. Enter dynamic viscosity and wall distance in millimeters.
  3. Read friction velocity and dimensionless y+.

Examples

  • ρ=1 kg/m³, τw=4 Pa, μ=0.001 Pa·s and y=0.5 mm give uτ=2 m/s and y+=1.

Frequently asked questions

Where is wall distance measured?

Use the distance normal to the wall to the point being evaluated, usually the first cell center in CFD.

How is wall shear stress obtained?

Enter a measured or separately computed value; this tool does not infer it from a friction correlation.

Does y+ alone approve a mesh?

No. The required range depends on the turbulence model, wall treatment and flow; check those requirements separately.

Sources

Updated:

Related tools

Search conversion tools