Faraday's Law Calculator
Calculate average induced emf in a coil from turn count, magnetic flux per turn and elapsed time.
Formula
Average emf = −N(Φ₂ − Φ₁)/Δt.
Average induced emf ≈ -(100)×((0.02)-(0))÷(0.1)
How to use
- Enter the positive whole number of coil turns.
- Enter initial and final signed flux per turn in Wb.
- Enter positive elapsed time and read average emf in volts.
Examples
- 100 turns changing from 0 to 0.02 Wb per turn in 0.1 s give −20 V.
Frequently asked questions
Is this instantaneous emf?
Only if flux changes at a constant rate. Otherwise it is the interval average.
What does the minus sign mean?
The induced emf opposes the flux change under the chosen loop orientation, as described by Lenz's law.
Do I enter flux or flux linkage?
Enter magnetic flux through one turn. The tool multiplies by N, assuming equal flux in every turn.
Sources