Wet-Bulb Temperature Calculator
Estimate wet-bulb temperature from air temperature and relative humidity with the Stull approximation near sea level.
Formula
Tw = T·atan(0.151977√(RH+8.313659)) + atan(T+RH) − atan(RH−1.676331) + 0.00391838·RH^1.5·atan(0.023101·RH) − 4.686035.
Estimated wet-bulb temperature ≈ (25)×atan(0.151977×sqrt((40)+8.313659))+atan((25)+(40))-atan((40)-1.676331)+0.00391838×(40)^1.5×atan(0.023101×(40))-4.686035
How to use
- Enter dry-bulb air temperature from −20 to 50 °C.
- Enter relative humidity from 5% to 99%.
- Read the estimated wet-bulb temperature.
Examples
- At 25 °C and 40% relative humidity, the estimate is 16.384 °C.
Frequently asked questions
Is this an exact psychrometric calculation?
No. Stull is an empirical approximation near sea-level pressure; error increases for cold, dry air.
Is wet-bulb temperature the same as WBGT?
No. Wet-bulb globe temperature also accounts for radiation and, depending on conditions, dry-bulb temperature.
Can I use this to set a personal heat-exposure limit?
No. This estimates a physical quantity and does not assess individual heat tolerance or exposure safety.
Sources
Updated: